Products Center
Products Center
Provide high-quality production materials to customers
Epodil® 749
Epodil® 749
Epodil® 749
Epodil® 749
Epoxy Curing Agents and Modifiers
Epodil 749 is neopentyl glycol diglycidyl ether used to reduce the viscosity of epoxy resin systems. It is a difunctional reactive diluent, which provides good viscosity reduction with minimal reduction in physical properties.
Category:Hardener

ADVANTAGES

• Good dilution efficiency

• Low volatility

• Good maintenance of properties


749.jpg

APPLICATIONS

• Laminates

• Flooring and mortors

• Potting and encapsulation


SHELF LIFE

At least 12 months from the date of manufacture in the original sealed container at ambient temperature.


STORAGE AND HANDLING

Refer to the Safety Data Sheet for Epodil 749 reactive diluent.


TABLE 1: TYPICAL PROPERTIES
AppearanceClear liquid
Color (Gardner)1 max
Viscosity @ 77°F (25°C), [mPa.s]10-25
Flash Point (closed cup) [°C]>93
Specific Gravity @ 70°F (21°C), [g/ml] 1.04
Equilalent Wt/{Epoxide}130-145
Free Water [%]0.2 max
Hydrolyzable Chloride [%]0.1 max

Free Epichlorohydrin [ppm]

10 max



TABLE 2: SUPPLEMENTARY DATA
Epodil 749 reactive diluent can be used as follows to lower the viscosity of a standard Bisphenol-A liquid epoxy resin (EEW=190) with an initial viscosity of 12,500 cP:
Weight Percent Epodil 749 (%)③Viscosity @ 77°F (25°C) (cP)②
55,000
102,500
151,300
20900


TABLE 3: EXAMPLE IMPACT OF DILUENT ON A SIMPLE FORMULATED SYSTEM

Evonik recommends that the formulator test reactive diluents in their system for performance. The following data is provided as an example of the impact of the reactive diluent on a simple formulated system. 


SYSTEM:

• BADGE with 12.5 wt% Epodil 749 

• Cured with Ancamine® 1618 curing agent at 1:1 stoichiometry


Property 

Without Epodil 749

With Epodil 749
Persoz hardness② at 23ºC (1 day/7day)195/31096/293
Phase 3 dry time③ (h) 7:109:31
Tg④ (1st scan)5148
Gel time⑤ (min)5555


2  BYK Persoz pendulum tester according to ISO 1522 with 10 mil WFT at 23˚C/50% RH

3  6 mil WFT BK Drying time recorder according to ASTM D5895  with 6 mil WFT at 23˚C/50% RH

4  TA Instruments DSC model Q200 first scan data

5  150g mix using TECHNE Gel-timer